MAX6654
1°C Accurate Remote/Local Temperature
Sensor with SMBus Serial Interface
Table 2. Data Format
extended temperature and read internal extended tem-
perature registers, which extend the resolution to
TEMP ( ° C)
130.00
127.00
126.00
25.25
0.50
0.00
<0.00 (Note 1)
-1
<-64
Diode fault
(short or open)
ROUNDED TEMP ( ° C)
+127
+127
+126
+25
+1
0
(Normal mode)
(Extended temp mode)
(Extended temp mode)
DIGITAL
OUTPUT
0 111 1111
0 111 1111
0 111 1110
0 001 1001
0 000 0001
0 000 0000
1 000 0000
1 111 1111
1 000 0000
1 000 0000
0.125°C per LSB (Table 3).
If a conversion ends after reading the main register but
before reading the extended register, the extended
register will contain the 3LSBs from the new conversion
while the main register will contain the 8MSBs from the
previous conversion. The extended data in this case
will be meaningless. To avoid this problem, read
extended resolution temperature data using one of the
following approaches:
1) Put the MAX6654 into standby mode by setting bit 6
of the configuration register to 1. Initiate a one-shot
conversion using Command Byte 0Fh. When this
conversion is complete, read the contents of the
temperature data registers.
2) If the MAX6654 is in run mode and the conversion
Table 3. Extended Resolution Register
rate is not set to either 1Hz or 8Hz, read the Status
Byte. If the BUSY bit indicates that a conversion is
FRACTIONAL
TEMPERATURE
0.000
0.125
0.250
0.375
0.500
0.625
0.750
0.875
DIGITAL OUTPUT
000X XXXX
001X XXXX
010X XXXX
011X XXXX
100X XXXX
101X XXXX
110X XXXX
111X XXXX
in progress, wait until the conversion is complete as
indicated by the BUSY bit. Then immediately read
the contents of the temperature data registers. If no
conversion is in progress, the data can be read
within a few μs, which is a sufficiently short period
to ensure that a new conversion can’t be completed
until after the data has been read.
Note: Extended resolution applies only for conversion
speeds of 1Hz and below.
Alarm Threshold Registers
Four registers store alarm threshold data, with high-
temperature (T HIGH ) and low-temperature (T LOW ) reg-
When the conversion rate is greater than 1Hz, tempera-
ture data can be read from the read internal tempera-
ture (00h) and read external temperature (01h)
registers. The temperature data format is 7 bits plus
sign in two’s-complement form for each channel, with
the LSB representing 1°C (Table 2), transmitted MSB
first. When the conversion rate is less than 1Hz, the
extended data can be read from the read external
extended temperature register (10h) and the read inter-
nal extended temperature register (11h), and the first 3
bits of the register represent 1/2, 1/4, and 1/8 of a
degree. Measurements are offset by +1/2°C to mini-
mize quantization errors; for example, +99.6°C is
reported as +100°C.
When the conversion rate is 1Hz or less, the first 8 bits
of temperature data can be read from the read internal
temperature (00h) and read external temperature (01h)
registers, the same as for faster conversion rates. An
additional 3 bits can be read from the read external
Maxim Integrated
isters for each A/D channel. If either measured
temperature equals or exceeds the corresponding
alarm threshold value, an ALERT interrupt is asserted.
The POR state of both T HIGH registers is full scale
(0111 1111, or +127°C). The POR state of both T LOW
registers is 1100 1001 or -55°C.
Diode Fault Alarm
There is a continuity fault detector at DXP that detects
whether the remote diode has an open-circuit condition
or if DXP is shorted to DXN, GND, or V CC . If an open
circuit exists, then the temperature register will be
loaded with 1000 0000, and bit 3 of the status register
will be set to 1 at the end of a conversion. This means
that immediately after POR the status byte will indicate
no fault is present until the end of the first conversion.
11
相关PDF资料
MAX6655EVSYS EVAL KIT FOR MAX6655
MAX6660EVKIT EVAL KIT FOR MAX6660
MAX6662EVKIT+ EVALUATION KIT FOR MAX6662
MAX6683EVKIT EVAL KIT FOR MAX6683
MAX6969EVKIT+ KIT EVAL FOR MAX6969
MAX7500EVKIT+ KIT EVAL FOR MAX7500
MAX8630XEVKIT+ KIT EVAL FOR MAX8630X MAX8630W
MAX8678EVKIT+ KIT EVAL FOR MAX8678
相关代理商/技术参数
MAX6654EVSYS 功能描述:板上安装温度传感器 Evaluation System for the MAX6654 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6654MEE 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6654MEE+ 功能描述:板上安装温度传感器 1C Accurate Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6654MEE+T 功能描述:板上安装温度传感器 1C Accurate Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6654MEET 制造商:MAXIM 功能描述:New
MAX6654MEE-T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6654YMEE+ 功能描述:板上安装温度传感器 1C Accurate Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6654YMEE+T 功能描述:板上安装温度传感器 1C Accurate Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor